Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 29(Suppl 1): S11525, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420498

RESUMO

Significance: To ensure precise tumor localization and subsequent pathological examination, a metal marker clip (MC) is placed within the tumor or lymph node prior to neoadjuvant chemotherapy for breast cancer. However, as tumors decrease in size following treatment, detecting the MC using ultrasound imaging becomes challenging in some patients. Consequently, a mammogram is often required to pinpoint the MC, resulting in additional radiation exposure, time expenditure, and increased costs. Dual-modality imaging, combining photoacoustic (PA) and ultrasound (US), offers a promising solution to this issue. Aim: Our objective is to localize the MC without radiation exposure using PA/US dual-modality imaging. Approach: A PA/US dual-modality imaging system was developed. Utilizing this system, both phantom and clinical experiments were conducted to demonstrate that PA/US dual-modality imaging can effectively localize the MC. Results: The PA/US dual-modality imaging can identify and localize the MC. In clinical trials encompassing four patients and five MCs, the recognition rate was ∼80%. Three experiments to verify the accuracy of marker position recognition were successful. Conclusions: We effectively localized the MC in real time using PA/US dual-modality imaging. Unlike other techniques, the new method enables surgeons to pinpoint nodules both preoperatively and intraoperatively. In addition, it boasts non-radioactivity and is comparatively cost-effective.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Terapia Neoadjuvante , Ultrassonografia/métodos , Linfonodos/patologia , Instrumentos Cirúrgicos
2.
Nat Commun ; 13(1): 7604, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494360

RESUMO

Photoacoustic endoscopy shows promise in the detection of gastrointestinal cancer, inflammation, and other lesions. High-resolution endoscopic imaging of the hemodynamic response necessitates a small-sized, high-sensitivity ultrasound sensor. Here, we utilize a laser ultrasound sensor to develop a miniaturized, optical-resolution photoacoustic endoscope. The sensor can boost the acoustic response by a gain factor of ωo/Ω (the frequency ratio of the signal light and measured ultrasound) by measuring the acoustically induced optical phase change. As a result, we achieve a noise-equivalent pressure density (NEPD) below 1.5 mPa·Hz-1/2 over the measured range of 5 to 25 MHz. The heterodyne phase detection using dual-frequency laser beams of the sensor can offer resistance to thermal drift and vibrational perturbations. The endoscope is used to in vivo image a rat rectum and visualize the oxygen saturation changes during acute inflammation, which can hardly be observed with other imaging modalities.


Assuntos
Técnicas Fotoacústicas , Ratos , Animais , Técnicas Fotoacústicas/métodos , Ultrassonografia , Acústica , Endoscopia , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...